Predicate research for 510(k) submissions

Find cleared devices with the same intended use and technology, see which predicates they cited, and keep the evidence for your substantial equivalence argument.
Updated Oct 12, 2026

The problem

Comparing thirty 510(k) summaries by hand takes days, so most teams sample five and hope the strongest predicate is among them. The ones they skip are often the scanned summaries keyword search cannot read.

How Bearnier AI does it

  1. 1

    Describe your device

    Type its intended use and technology the way you would brief a colleague, or enter its product code.

  2. 2

    Compare the candidates

    Bearnier AI reads every summary under the code and lines up intended use, technology and the predicates each one cited.

  3. 3

    Keep the evidence

    Export the comparison to Word with every cell linked to its page, ready for your substantial equivalence section.

Questions to try

Pick one to run it, or write your own.

US FDA devices: 510(k), De Novo, guidance, 21 CFR

A finished answer

What predicates have recent AI triage devices cited, and what testing did FDA expect?

Cited 7 sources · counted 88 FDA records
  1. Mapping the question to product code QAS
  2. Reading 88 records under 21 CFR 892.2080
  3. Opening De Novo decision summary DEN170073
  4. Opening 510(k) summaries K261085, K260729 and K261317
  5. Extracting predicates and standalone performance

AI triage devices are cleared under product code QAS, a Class II device regulated at 21 CFR 892.2080 , with 88 510(k) records in openFDA . The category was created by De Novo DEN170073, Viz.ai’s ContaCT .

Recent submitters cite an earlier cleared triage device, not the De Novo. K261085, iSchemaview’s Rapid VO, cleared Jul 13, 2026 , flags suspected large vessel occlusion on adult head CTA and names the company’s own Rapid CTA 360, K251151 . K260729, GuideAI Health’s VAOT, cleared Jun 18, 2026 , names Aidoc’s BriefCase LVO Triage, K220709 , although VAOT flags occlusions in the aorta and the iliac, femoral and popliteal arteries . Aidoc’s own Special 510(k), K261317, also names K220709 .

FDA accepted standalone performance on a few hundred multi-site cases, reported as sensitivity and specificity with 95% confidence intervals, plus time to notification:

  1. K261085: 314 CTA cases from 33 clinical sites (99.0% US), 282 evaluable with 113 positive and 169 negative . Sensitivity 0.956 (95% CI 0.901–0.981), specificity 0.905 (95% CI 0.852–0.941), mean time to notification 3.2 to 3.3 minutes
  2. K260729: 317 cases from US sites, 165 positive and 152 negative . Sensitivity 0.915 (95% CI 0.862–0.953), specificity 0.901 (95% CI 0.842–0.944), time to notification under 5 minutes

In both, ground truth came from three board-certified radiologists by majority vote .

13 citations
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open

Find a predicate in ten seconds

Free, no account. Straight from FDA’s 510(k) database.

Try
Product code FRN · 21 CFR 880.5725 · 849 clearances in FDA’s database
510(k)DeviceApplicantDecision
K253703RemunityPRO+ Pump for Remodulin® (treprostinil) InjectionDeka R&D CorpJul 24, 2026
K252015FreedomEdge Infusion System; High-Flo SubQ Needle Set; Precision Flow Rate TubingKoru Medical Systems, Inc.Jan 28, 2026
K251636Spectrum IQ Infusion System with Dose IQ Safety Software (3570009)Baxter Healthcare CorporationJul 28, 2025
K251640SIGMA Spectrum Infusion Pump with Master Drug LibraryBaxter Healthcare CorporationJul 28, 2025
K242752MRidium 3870 MRI Infusion Pump System (3870)Iradimed CorporationMay 28, 2025
K243855BD Alaris Infusion System with Guardrails Suite MXCarefusion 303, Inc.Apr 25, 2025
Showing 6 of 849 · From FDA’s 510(k) database, as of Nov 16, 2026
Follow your product codeGet an email when FDA clears a device that could be your predicate.

Know what FDA already cleared.