DPS: Electrocardiograph
What it covers
Devices that acquire and record the electrical activity of the heart, from diagnostic 12-lead systems to wearable ECG patches, often with software that measures intervals or detects arrhythmias.
Recent clearances
| 510(k) | Device | Applicant | Decision | Type |
|---|---|---|---|---|
| K260640 | Kinetic Software Library | Monebo Technologies, Inc. | Oct 23, 2026 | Traditional |
| K260005 | MyoVista wavECG (DG-200-B15-003) | HeartSciences, Inc. | Oct 5, 2026 | Traditional |
| K260250 | QCA 10 Electrocardiograph (QCARD-10); QCA 10W Electrocardiograph (QCARD-10W) | QT Medical, Inc. | Sep 29, 2026 | Traditional |
| K252463 | SE-1202 Series Electrocardiograph (Model: SE-1202, SE-1202E) | Edan Instruments, Inc. | Jul 2, 2026 | Traditional |
| K251670 | MAC 7 Resting ECG Analysis System | Ge Medical Systems Information Technologies, Inc. | Jan 26, 2026 | Traditional |
| K252361 | AccurECG Analysis System (v2.0) | Accurkardia, Inc. | Dec 22, 2025 | Traditional |
| K252474 | Withings BeamO (SCT02) | Withings | Nov 10, 2025 | Traditional |
| K250569 | Cardiologs Holter Platform | Philips France Commercial | Aug 6, 2025 | Traditional |
| K243252 | ZBPro Diagnostic | Zbeats, Inc. | Jul 10, 2025 | Traditional |
| K243305 | Masimo W1 | Masimo Corporation | Apr 3, 2025 | Traditional |
Clearances by year
146 DPS 510(k)s were cleared from 2011 to Oct 29, 2026. Days to decision run from the day FDA received the 510(k) to its decision, including time on hold.
| Year | Clearances | Median days to decision |
|---|---|---|
| 2026 (so far) | 5 | 270 |
| 2025 | 6 | 163 |
| 2024 | 8 | 260 |
| 2023 | 10 | 236 |
| 2022 | 6 | 244 |
| 2021 | 5 | 135 |
| 2020 | 6 | 224 |
| 2019 | 3 | 178 |
| 2018 | 14 | 221 |
| 2017 | 9 | 177 |
| 2016 | 11 | 229 |
| 2015 | 8 | 178 |
| 2014 | 11 | 253 |
| 2013 | 10 | 134 |
| 2012 | 12 | 117 |
| 2011 | 22 | 154 |
Who submits
88 applicants cleared a DPS device since 2011. 48% of the clearances went to applicants in United States, then China (27%), France (5%) and South Korea (4%). By type: Traditional 85%, Special 13% and Abbreviated 2%. 5 went through a third-party review organization.
| Applicant | Clearances since 2011 |
|---|---|
| Edan Instruments, Inc. | 13 |
| Ge Medical Systems Information Technologies, Inc. | 6 |
| Bionet Co., Ltd. | 5 |
| Mortara Instrument, Inc. | 5 |
| Shenzhen Biocare Bio-Medical Equipment Co., Ltd. | 5 |
| AliveCor, Inc. | 4 |
| Philips Medical Systems | 4 |
| Shenzhen Biocare Electronics Co., Ltd. | 4 |
Testing FDA usually expects
- Electrical safety and EMC per IEC 60601-1 and IEC 60601-1-2
- ECG performance per IEC 60601-2-25 (diagnostic) or IEC 60601-2-47 (ambulatory)
- Arrhythmia algorithm performance against reference databases per ANSI/AAMI EC57
- Biocompatibility of skin-contacting parts per ISO 10993-1
Standards
Ask about DPS
Questions about DPS
What is FDA product code DPS?
Product code DPS covers electrocardiographs, Class II devices regulated under 21 CFR 870.2340 and reviewed by FDA's Cardiovascular panel. FDA's 510(k) database lists 579 clearances under DPS.
How many 510(k) clearances are there under DPS?
FDA’s 510(k) database listed 579 clearances under DPS as of Nov 16, 2026, 146 of them decided since 2011; the most recent decision was Oct 23, 2026. The Predicate Finder searches the live database.
How long does FDA take to clear a DPS 510(k)?
For the 12 DPS clearances decided in the two years before Oct 29, 2026, the median time from FDA receiving the 510(k) to its decision was 243 days. That counts calendar days, including time the submission was on hold waiting for answers from the submitter.
Which companies have the most DPS clearances?
Since 2011: Edan Instruments, Inc. (13), Ge Medical Systems Information Technologies, Inc. (6), Bionet Co., Ltd. (5), Mortara Instrument, Inc. (5) and Shenzhen Biocare Bio-Medical Equipment Co., Ltd. (5). 88 applicants have cleared a DPS device in that time.
What testing do DPS submissions include?
Recent DPS 510(k) summaries typically describe: electrical safety and EMC per IEC 60601-1 and IEC 60601-1-2; eCG performance per IEC 60601-2-25 (diagnostic) or IEC 60601-2-47 (ambulatory); arrhythmia algorithm performance against reference databases per ANSI/AAMI EC57; biocompatibility of skin-contacting parts per ISO 10993-1. Check the summaries of your own predicates for what they submitted.