Premarket cybersecurity checklist for connected devices

If your device runs software and can connect to the internet, section 524B of the FD&C Act applies: your premarket submission must include a plan to monitor and address postmarket vulnerabilities, evidence of a secure development process, and a software bill of materials. FDA’s cybersecurity guidance sets out the documentation it expects for each.
Written by the Bearnier AI team · Updated Oct 12, 2026 · 7 min read
1

Check whether your device is a cyber device

Section 524B covers devices that include software, can connect to the internet, and could be vulnerable to cybersecurity threats. If yours qualifies, the cybersecurity content below is required, not optional.

2

Build a threat model and security risk assessment

Map the system, its interfaces and trust boundaries, then assess threats and controls in a security risk management report that sits alongside, not inside, your safety risk file.

3

Write the software bill of materials

List commercial, open-source and off-the-shelf components with versions, their support status and end-of-support dates, and assess known vulnerabilities in each.

4

Document the security architecture

Provide architecture views that show how authentication, authorization, encryption, integrity and updates work across the device and its connected systems.

5

Test the controls

Include security testing such as vulnerability scanning, penetration testing, fuzz testing and static analysis, with findings and how each was resolved or justified.

6

Plan for the postmarket

Describe how you will monitor, identify and address vulnerabilities, including coordinated vulnerability disclosure and how and how fast you will ship patches, and give users the security information they need in labeling.

Try it on your device

Bearnier AI shows what cybersecurity documentation recent clearances in your product code described.

US FDA devices: 510(k), De Novo, guidance, 21 CFR
Get new guides in The Clearance LogOne email every Monday. Five minutes, every item cited.

Questions

Does this apply to 510(k), De Novo and PMA?

Yes. Section 524B applies to premarket submissions for cyber devices across pathways, and FDA’s cybersecurity guidance covers 510(k), De Novo, PMA and other submission types.

What if my device is not connected?

Section 524B covers devices that can connect to the internet. Devices with other interfaces, such as USB or Bluetooth, should still address cybersecurity risk under the quality system and FDA’s guidance.

Can Bearnier AI show what FDA accepted?

Yes. Ask about your product code and Bearnier AI lists the cybersecurity documentation recent summaries describe, cited to the page.