How to classify a medical device with FDA: product code, class and pathway

To classify a medical device with FDA, confirm the product meets the device definition in section 201(h), find the classification regulation and three-letter product code for its device type in FDA’s Product Classification database, read the class it assigns, check whether the device is exempt from 510(k), and take the premarket pathway that follows. When no classification fits, ask FDA with a 513(g) Request for Information.
Written by the Bearnier AI team · Updated Oct 29, 2026 · 6 min read
1

Confirm your product is a medical device

Under section 201(h) of the FD&C Act, a device is an instrument, apparatus, machine, implant, in vitro reagent or similar article intended for the diagnosis, cure, mitigation, treatment or prevention of disease, or to affect the structure or function of the body, that does not achieve its primary purpose through chemical action. If it does not meet the definition, FDA’s device classifications do not apply.

2

Write the intended use and how the device works

Classification follows the device type, and the device type follows what the device is for and how it does it. Name the condition, the user, the setting and the core technology in plain words before you search.

3

Find the regulation and product code

FDA has classified about 1,700 generic device types into 16 medical specialty panels, in 21 CFR parts 862 to 892. Search the Product Classification database for part of the device name, or browse your panel. FDA also suggests looking at similar devices in its 510(k), De Novo and PMA databases. Each device type has a regulation, numbered like 21 CFR 880.2920, and a three-letter product code.

4

Read the class and its controls

Class I devices are subject to general controls, Class II to general and special controls, and Class III to general controls and premarket approval. Classification is risk based, from lowest (Class I) to highest (Class III). For Class II, read the special controls in the regulation: they shape the testing you will need.

5

Check whether the device is exempt from 510(k)

Most Class I and some Class II devices are exempt from 510(k). The limits on each exemption are in sections 862.9 to 892.9, and FDA can limit an exemption to some devices within a regulation, so confirm it for your product code. Exempt devices still follow the other regulatory controls, such as the quality management system regulation.

6

Take the pathway that follows, or ask FDA

A Class I or II device that is not exempt needs a 510(k); a Class III device needs a PMA unless it is a preamendments device; a novel low-to-moderate-risk device with no classification may fit De Novo. When nothing fits, a 513(g) Request for Information asks FDA for the class and requirements in writing: it carries a user fee, and FDA intends to respond within 60 days.

Try it on your device

Describe the device; Bearnier AI proposes candidate product codes with their class, regulation and pathway, each cited to the FDA record.

US FDA devices: 510(k), De Novo, guidance, 21 CFR
Get new guides in The Clearance LogOne email every Monday. Five minutes, every item cited.

Questions about classification

Is there an AI tool that can classify my device?

Yes. Describe the device to Bearnier AI and it proposes candidate product codes with their class, regulation and pathway, each cited to the FDA record. Confirm the code in FDA’s Product Classification database before you rely on it. See the device classification tools, compared.

What if my device fits no classification?

A post-amendments device with no classification is Class III by default. If it is low to moderate risk, De Novo can classify it; when you are unsure, a 513(g) request asks FDA directly.

Is a 513(g) response binding?

No. FDA says a 513(g) response does not constitute final agency action; it gives information based on what you submitted.

Can one regulation have several product codes?

Yes. A regulation describes a generic device type, and FDA can assign several product codes under it, sometimes with different exemption status, so check the exemption for your product code, not just the regulation.

Know what FDA already cleared.