The options, and when each fits
1FDA’s Product Classification database
Fits when: You know, or can guess, what FDA calls your device type, and want the authoritative answer.
Free and the primary source. FDA has classified about 1,700 generic device types into 16 medical specialty panels, in 21 CFR parts 862 to 892. Search by part of the device name, product code, review panel, regulation number, device class or submission type, and each record gives the three-letter product code, class and regulation. It matches names, not descriptions: if FDA calls your device something you would not, you will not find it.
2Bearnier AI
Fits when: You can describe what the device does but not what FDA calls it, and want the evidence behind each candidate.
Describe the device and its intended use in plain language, and Bearnier AI proposes candidate product codes with their class, regulation and likely pathway, cited to FDA’s classification records, the regulation text in 21 CFR and the 510(k) and De Novo decisions of devices like yours. It also covers predicates, testing and standards for the code you pick. US FDA only today. We make it, so weigh this entry accordingly and test it on a device you already know.
3ELLA by StarFish Medical
Fits when: You want a free assistant across FDA guidance, panel transcripts and adverse events.
StarFish Medical, a device design and manufacturing firm, describes ELLA as able to search FDA guidance documents, advisory panel transcripts, MAUDE adverse event reports and other public regulatory databases. Its page says it is currently available at no cost.
4Complizen
Fits when: You want classification, predicates and submission drafting in one workspace, with consulting on the side.
Complizen lists a device classification database of more than 1,700 device categories with 21 CFR citations, product codes and special controls, searched by device, product code or plain-English question, plus a predicate finder and drafting agents. Published plans run from $66 a month, with a free plan for early-stage startups and students who apply. It also sells fixed-fee 510(k) consulting.
5General AI assistants
Fits when: You want the concepts explained: what the classes mean, what a special control is.
ChatGPT, Claude and Gemini answer from training data and the open web, not from an index of FDA’s record. They can state product codes or regulation numbers that do not exist or belong to a different device type. Treat any code they give you as unverified until you have opened it in FDA’s database.
6A 513(g) Request for Information
Fits when: Your device does not fit any classification cleanly, or it is unclear whether it is a device at all.
FDA’s own written statement of the class and requirements that apply to your device. It carries a user fee, covers one product per request, and FDA intends to respond within 60 days of receipt. The response is not final agency action, and it is based only on the information you submit.
7Regulatory consultants
Fits when: The classification drives a pathway decision you need someone accountable for.
Experienced consultants know how FDA has treated borderline devices, and when a Pre-Submission or a De Novo is the better path. They cost more and take longer, and they search the same FDA databases.
Side by side
| Option | Cost | Input | Sources | Cites the record |
|---|
| FDA Product Classification database | Free | Device name, code, panel, regulation | FDA classification records | It is the record |
| Bearnier AI | Free for 3 answers a month; Pro $250/month | Plain description or product code | FDA classification, 21 CFR, 510(k), De Novo, guidance | Yes, every precise fact, to the page |
| ELLA | Currently free, per StarFish | Plain question | FDA guidance, panel transcripts, MAUDE, other public databases | Not stated on its page |
| Complizen | From $66/month; free plan by application | Device, product code or question | Its classification database, 21 CFR, guidance | Says outputs are cited |
| General AI assistants | Free and paid plans | Plain question | Training data and the open web | No; codes need checking |
| 513(g) request | FDA user fee | A written request with device description and labeling | FDA’s own review | FDA’s written response |
| Regulatory consultants | Hourly or project fees | A conversation | FDA databases, plus experience | In their report |
Bearnier AI’s entries describe our own product. ELLA and Complizen are described from their own websites, and the FDA entries from FDA’s pages, all read Oct 28, 2026; we have not tested the other tools’ answers.
How FDA classification works
Whichever tool suggests a classification, these are the checks that confirm it.
1. Confirm it is a device
A product is a device under section 201(h) of the FD&C Act when it is intended for the diagnosis, cure, mitigation, treatment or prevention of disease, or to affect the structure or function of the body, without achieving its primary purpose through chemical action.
2. Find the classification regulation
Search FDA’s Product Classification database by part of the device name, or browse your panel. Each device type has a regulation in 21 CFR parts 862 to 892, numbered like 21 CFR 880.2920, and a three-letter product code.
3. Read the class
Class I devices are subject to general controls, Class II to general and special controls, and Class III to general controls and premarket approval. Classification is risk based: Class I is the lowest risk, Class III the highest.
4. Check for an exemption
Most Class I and some Class II devices are exempt from 510(k). Exemptions have limits, set out in sections 862.9 to 892.9 of each part, and FDA can limit an exemption to some devices within a regulation, so confirm the exemption for your product code. Exempt devices still follow the other regulatory controls, such as the quality management system regulation.
5. Read off the pathway
A Class I or II device that is not exempt needs a 510(k). A Class III device needs a PMA unless it is a preamendments device. A novel device with no classification may fit De Novo if it is low to moderate risk.
6. Ask FDA when it is unclear
Use a 513(g) Request for Information when no classification fits or the product may not be a device. For questions about testing and the pathway as well, a Pre-Submission lets you ask FDA before you commit.
The full walk-through is in how to classify a medical device with FDA, and every busy product code has its own page, with its regulation, class and recent clearances.
Describe your device
Bearnier AI proposes candidate product codes with their class, regulation and pathway, and the FDA page behind each.
Questions about device classification
Is there an AI tool that can classify my medical device for FDA?
Yes. AI tools such as Bearnier AI, ELLA and Complizen accept a plain description and point to likely classifications. Bearnier AI proposes candidate product codes with their class, regulation and pathway, each cited to the FDA record. No AI answer is a classification decision: confirm the code in FDA’s Product Classification database, and ask FDA with a 513(g) request when it is unclear.
How do I find the FDA product code for my device?
Search FDA’s Product Classification database by part of the device name, or by panel if you know it. If you only know what the device does, describe it to an AI tool that searches FDA’s record, then open the suggested codes in the database to confirm the class, regulation and any 510(k) exemption.
What are the three FDA device classes?
Class I devices are subject to general controls, Class II to general and special controls, and Class III to general controls and premarket approval. FDA assigns the class by risk, from lowest (Class I) to highest (Class III).
Can ChatGPT tell me my device class?
It can explain the classes and suggest where to look, but it does not search FDA’s classification database and can give product codes or regulation numbers that do not exist or belong to another device. Check every code it gives you in FDA’s database.
What is a 513(g) request?
A written request asking FDA which class your device is in and which requirements apply. It carries a user fee and covers one product. FDA intends to respond within 60 days, and the response is not final agency action.
Does a Class I device need a 510(k)?
Usually not: most Class I and some Class II devices are exempt from 510(k), subject to the limitations in each classification regulation. A Class I or II device that is not exempt needs a 510(k).
Sources
- Classify Your Medical Device · FDA, content current as of Aug 26, 2026
- Product Classification database · FDA, accessdata.fda.gov
- Device Classification Panels · FDA, content current as of Aug 26, 2026
- Class I and Class II Device Exemptions · FDA, content current as of Oct 6, 2026
- How to Determine if Your Product is a Medical Device · FDA, content current as of Sep 29, 2022
- FDA and Industry Procedures for Section 513(g) Requests for Information under the Federal Food, Drug, and Cosmetic Act · FDA final guidance, Aug 2024 · docket FDA-2010-D-0153
- Premarket Notification 510(k) · FDA, content current as of Aug 22, 2024
- De Novo Classification Request · FDA
- Premarket Approval (PMA) · FDA
- Requests for Feedback and Meetings for Medical Device Submissions: The Q-Submission Program · FDA final guidance, May 2025 · docket FDA-2018-D-1774
- Meet ELLA · StarFish Medical, read Oct 28, 2026
- Complizen pricing · Complizen, read Oct 28, 2026
- Complizen Knowledge · Complizen, read Oct 28, 2026