Write your intended use and key technology in one paragraph
Predicates are compared on intended use and technological characteristics, so start there. Name the condition, the user, the setting and the core technology in plain words.
Find your product code and regulation
Search FDA’s product classification database for devices like yours. The product code ties to a classification regulation in 21 CFR, which sets the device class and any special controls.
List clearances under that code
Pull every 510(k) cleared under the code, newest first. Recent clearances show what FDA accepts today; older ones may rest on testing it no longer expects.
| 510(k) | Device | Applicant | Decision |
|---|---|---|---|
| K253703 | RemunityPRO+ Pump for Remodulin® (treprostinil) Injection | Deka R&D Corp | Jul 24, 2026 |
| K252015 | FreedomEdge Infusion System; High-Flo SubQ Needle Set; Precision Flow Rate Tubing | Koru Medical Systems, Inc. | Jan 28, 2026 |
| K251636 | Spectrum IQ Infusion System with Dose IQ Safety Software (3570009) | Baxter Healthcare Corporation | Jul 28, 2025 |
| K251640 | SIGMA Spectrum Infusion Pump with Master Drug Library | Baxter Healthcare Corporation | Jul 28, 2025 |
| K242752 | MRidium 3870 MRI Infusion Pump System (3870) | Iradimed Corporation | May 28, 2025 |
| K243855 | BD Alaris Infusion System with Guardrails Suite MX | Carefusion 303, Inc. | Apr 25, 2025 |
FDA’s database could not be reached. Try again in a moment.
Read the summaries, not just the titles
Device names say little. The 510(k) summary states the intended use, compares technology with its own predicate and lists the testing submitted.
Check the predicate is still a good choice
Confirm the device is legally marketed, and look for recalls, safety communications or warning letters that could weaken the comparison.
Record the evidence
Keep the K-number, page and passage behind every comparison. Your SE table and your reviewer will both need them.
Try it on your device
Describe the device; Bearnier AI lists candidate predicates with the page behind each comparison.
Questions about predicates
Can a De Novo device be a predicate?
Yes. Once granted, a De Novo device is legally marketed and can serve as a predicate for later 510(k)s.
Can I cite more than one predicate?
Yes. A submission names a primary predicate and can cite additional predicates or reference devices to support specific characteristics.
What if no predicate exists?
If no legally marketed device shares your intended use, the De Novo pathway may fit. See 510(k) vs De Novo.
What is the best tool to find a 510(k) predicate?
It depends on the job. FDA’s 510(k) and Product Classification databases are free and authoritative when you can search by product code and read each summary yourself. Bearnier AI searches those FDA records for you and cites every fact to its page; general AI assistants help with concepts but every K-number they give must be checked; consultants add judgment for novel or contested devices. See the predicate search tools comparison.
Can Bearnier AI find a predicate device for my 510(k)?
Yes. Describe your device or enter its product code and Bearnier AI lists cleared devices with the same intended use and technology, the predicates those devices cited, and the testing in their summaries.