OAT: Implant, Endosseous, Orthodontic
What it covers
It is intended to provide a fixed anchorage point for attachment of orthodontic appliances to facilitate the orthodontic movement of teeth. It is used temporarily and is removed after orthodontic treatment has been completed.
FDA’s definition of product code OAT, from the Product Classification database.
FDA flags OAT devices as implants.
Recent clearances
| 510(k) | Device | Applicant | Decision | Type |
|---|---|---|---|---|
| K260268 | OrthoEasy Pal; OrthoEasy Pal Long Neck | Bernhard Förster GmbH (Bernhard Foerster Ltd.) | May 19, 2026 | Traditional |
| K242944 | Leone Orthodontic Implant TAD (Temporary Anchorage Device) | Leone S.P.A. | Jun 19, 2025 | Traditional |
| K231502 | Mini Screws | Proimtech Saglik Urunleri Anonim Sirketi | Sep 4, 2024 | Traditional |
| K231913 | T-FIT | Techwin Co., Ltd. | Feb 8, 2024 | Traditional |
| K222245 | ACR Screw System | Biomaterials Korea, Inc. | Aug 21, 2023 | Traditional |
| K202163 | Mico One Orthodontic Screw | Ze Fang Technology Co., Ltd. | Oct 7, 2022 | Traditional |
| K202691 | Ortholock Anchorage Devices | Craniofacial Technologies, Inc. | Apr 28, 2022 | Traditional |
| K210559 | ATOZ Mini-Screw | Mk Meditech, Inc. | Dec 19, 2021 | Traditional |
| K211992 | Ortho MI System | Osteonic Co., Ltd. | Oct 15, 2021 | Traditional |
| K202790 | Syntec Orthodontic Mini Screw Extended System | Syntec Scientific Corporation | Sep 17, 2021 | Special |
Clearances by year
30 OAT 510(k)s were cleared from 2011 to Oct 29, 2026. Days to decision run from the day FDA received the 510(k) to its decision, including time on hold.
| Year | Clearances | Median days to decision |
|---|---|---|
| 2026 (so far) | 1 | 111 |
| 2025 | 1 | 267 |
| 2024 | 2 | 347 |
| 2023 | 1 | 391 |
| 2022 | 2 | 693 |
| 2021 | 4 | 224 |
| 2020 | 3 | 289 |
| 2019 | 2 | 330 |
| 2018 | 1 | 279 |
| 2017 | 1 | 287 |
| 2016 | 2 | 209 |
| 2015 | 1 | 238 |
| 2014 | 1 | 317 |
| 2013 | 2 | 303 |
| 2012 | 1 | 296 |
| 2011 | 5 | 152 |
Who submits
26 applicants cleared a OAT device since 2011. 33% of the clearances went to applicants in South Korea, then United States (33%), Taiwan (20%) and Germany (7%). By type: Traditional 87% and Special 13%.
| Applicant | Clearances since 2011 |
|---|---|
| Biomaterials Korea, Inc. | 3 |
| Bomei Co, Ltd. | 2 |
| Osstem Implant Co., Ltd. | 2 |
| Bernhard Förster GmbH (Bernhard Foerster Ltd.) | 1 |
| Biocetec Co., Ltd. | 1 |
| Blue Sky Bio, LLC | 1 |
| Bonafix Surgical and Dental Implants, LLC | 1 |
| Craniofacial Technologies, Inc. | 1 |
How FDA classifies it
(1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)
(2) Classification. Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:
(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
From 21 CFR 872.3640. Special controls are the requirements a 510(k) must show it meets.
Standards
21 CFR 872.3640 names no consensus standards. Check FDA’s recognized standards database, or ask which standards recent OAT clearances declared.
Ask about OAT
Questions about OAT
What is FDA product code OAT?
Product code OAT, “Implant, Endosseous, Orthodontic” in FDA's classification database, is a Class II device type under 21 CFR 872.3640 (endosseous dental implant), reviewed by FDA's Dental panel. FDA's 510(k) database lists 52 clearances under OAT, 30 of them since 2011.
How many 510(k) clearances are there under OAT?
FDA’s 510(k) database listed 52 clearances under OAT as of Oct 29, 2026, 30 of them decided since 2011; the most recent decision was May 19, 2026. The Predicate Finder searches the live database.
How long does FDA take to clear a OAT 510(k)?
For the 2 OAT clearances decided in the two years before Oct 29, 2026, the median time from FDA receiving the 510(k) to its decision was 189 days. That counts calendar days, including time the submission was on hold waiting for answers from the submitter.
Which companies have the most OAT clearances?
Since 2011: Biomaterials Korea, Inc. (3), Bomei Co, Ltd. (2), Osstem Implant Co., Ltd. (2), Bernhard Förster GmbH (Bernhard Foerster Ltd.) (1) and Biocetec Co., Ltd. (1). 26 applicants have cleared a OAT device in that time.