MWI: Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Product code MWI, “Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)” in FDA's classification database, is a Class II device type under 21 CFR 870.2300 (cardiac monitor (including cardiotachometer and rate alarm)), reviewed by FDA's Cardiovascular panel. FDA's 510(k) database lists 309 clearances under MWI, 179 of them since 2011.
Updated Oct 29, 2026 · Clearances from FDA’s 510(k) database, as of Oct 29, 2026
Product code
MWI
Regulation
21 CFR 870.2300
Class
II
Panel
Cardiovascular
Clearances
309
Most recent
Oct 16, 2026
Median review, last 2 years
223 days
Third-party review
Eligible
Implant
No

What it covers

A cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate from an analog signal produced by an electrocardiograph, vectorcardiograph, or blood pressure monitor. This device may sound an alarm when the heart rate falls outside preset upper and lower limits.

The identification in 21 CFR 870.2300, cardiac monitor (including cardiotachometer and rate alarm). FDA gives MWI no definition of its own, so the regulation’s describes it.

Recent clearances

510(k)DeviceApplicantDecisionType
K260801Sensinel Cardiopulmonary Management (CPM) SystemAnalog DevicesOct 16, 2026Traditional
K260438Vital Signs Monitor (CLEO2)Infinium Medical, Inc.Aug 14, 2026Traditional
K253417Masimo Root Monitoring SystemMasimo CorporationAug 12, 2026Traditional
K253196Midmark 800 Digital Vital Signs Device (1-300-0100, 1-300-0200, 1-300-0300, 1-300-0400)Midmark CorporationJun 12, 2026Traditional
K253436c-med0 alphaCosinuss GmbHApr 30, 2026Traditional
K250135WAVE Clinical Platform (2.0.000)Baxter Healthcare Corp/ Excel MedicalJan 16, 2026Traditional
K241766QMAPP® (Hemo, Hemo Lite, PCM, GO, Hybrid)Fysicon BVAug 27, 2025Traditional
K242737Empatica Health Monitoring Platform; EmbracePlus; Empatica Care; Care PortalEmpatica S.r.l.Jun 6, 2025Traditional
K241958WARD-CSS (v1.2.x)Ward 24/7 ApsFeb 14, 2025Traditional
K243146iCare APPIhealth Labs, Inc.Feb 3, 2025Traditional
From FDA’s 510(k) database, as of Oct 29, 2026Export CSV (100 rows free · all 309 with a free account)

Clearances by year

179 MWI 510(k)s were cleared from 2011 to Oct 29, 2026. Days to decision run from the day FDA received the 510(k) to its decision, including time on hold.

YearClearancesMedian days to decision
2026 (so far)6239
20254247
202410202
20238250
20225231
20219161
20208138
201914255
201811217
201713205
201612165
201519127
201416148
20132085
201213104
20111178

Who submits

89 applicants cleared a MWI device since 2011. 74% of the clearances went to applicants in United States, then China (11%), United Kingdom (3%) and India (2%). By type: Traditional 79%, Special 17% and Abbreviated 4%. 17 went through a third-party review organization.

ApplicantClearances since 2011
Masimo Corporation13
Welch Allyn, Inc.9
Airstrip Technologies, LP7
Guangdong Biolight Meditech Co., Ltd.7
Sotera Wireless, Inc.7
Invivo Corporation6
Etiometry, Inc.5
Capsule Technologie Sas4

How FDA classifies it

Class II (performance standards).

From 21 CFR 870.2300.

Standards

21 CFR 870.2300 names no consensus standards. Check FDA’s recognized standards database, or ask which standards recent MWI clearances declared.

Ask about MWI

US FDA devices: 510(k), De Novo, guidance, 21 CFR

Questions about MWI

What is FDA product code MWI?

Product code MWI, “Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)” in FDA's classification database, is a Class II device type under 21 CFR 870.2300 (cardiac monitor (including cardiotachometer and rate alarm)), reviewed by FDA's Cardiovascular panel. FDA's 510(k) database lists 309 clearances under MWI, 179 of them since 2011.

How many 510(k) clearances are there under MWI?

FDA’s 510(k) database listed 309 clearances under MWI as of Oct 29, 2026, 179 of them decided since 2011; the most recent decision was Oct 16, 2026. The Predicate Finder searches the live database.

How long does FDA take to clear a MWI 510(k)?

For the 12 MWI clearances decided in the two years before Oct 29, 2026, the median time from FDA receiving the 510(k) to its decision was 223 days. That counts calendar days, including time the submission was on hold waiting for answers from the submitter.

Which companies have the most MWI clearances?

Since 2011: Masimo Corporation (13), Welch Allyn, Inc. (9), Airstrip Technologies, LP (7), Guangdong Biolight Meditech Co., Ltd. (7) and Sotera Wireless, Inc. (7). 89 applicants have cleared a MWI device in that time.

Sources

  1. FDA product classification: MWI · Product Classification database
  2. 21 CFR 870.2300: Cardiac monitor (including cardiotachometer and rate alarm) · eCFR, as of Oct 27, 2026
  3. openFDA 510(k) query for MWI · run Oct 29, 2026
  4. 510(k) Premarket Notification database · FDA, accessdata.fda.gov
Follow MWIGet an email when FDA clears, recalls or publishes guidance for MWI devices.