MRN: Apparatus, Nitric Oxide Delivery
What it covers
The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be used in conjunction with a ventilator or other breathing gas administration system.
The identification in 21 CFR 868.5165, nitric oxide administration apparatus. FDA gives MRN no definition of its own, so the regulation’s describes it.
FDA flags MRN devices as life-sustaining or life-supporting.
Recent clearances
| 510(k) | Device | Applicant | Decision | Type |
|---|---|---|---|---|
| K242374 | ULSPIRA TS Nitric Oxide Therapy System | Airgas Therapeutics, LLC | Jan 17, 2025 | Special |
| K242578 | EVOLVE Nitric Oxide Delivery System | Mallinckrodt Manufacturing, LLC | Jan 3, 2025 | Special |
| K240410 | EVOLVE Nitric Oxide Delivery System | Malinckrodt Manufacturing, LLC | May 28, 2024 | Special |
| K233251 | NOxBOXi Nitric Oxide Delivery System | Linde Gas & Equipment, Inc. | May 23, 2024 | Traditional |
| K222930 | Evolve Nitric Oxide Delivery System | Mallinckrodt Manufacturing, LLC | Dec 6, 2023 | Traditional |
| K231823 | NOxBOXi Nitric Oxide Delivery System | Linde Gas & Equipment, Inc. | Aug 11, 2023 | Special |
| K212409 | Ulspira TS Nitric Oxide Therapy System | Airgas Therapeutics | Jun 30, 2023 | Traditional |
| K211153 | Inomax DSIR | Mallinckrodt Manufacturing, LLC | Apr 20, 2023 | Traditional |
| K220898 | NOxBOXi Nitric Oxide Delivery System | Linde Gas & Equipment, Inc. | Apr 27, 2022 | Special |
| K201339 | The NOxBOXi Nitric Oxide Delivery System | Praxair, Inc. | Jun 19, 2020 | Special |
Clearances by year
21 MRN 510(k)s were cleared from 2011 to Oct 29, 2026. Days to decision run from the day FDA received the 510(k) to its decision, including time on hold.
| Year | Clearances | Median days to decision |
|---|---|---|
| 2025 | 2 | 144 |
| 2024 | 2 | 172 |
| 2023 | 4 | 566 |
| 2022 | 1 | 30 |
| 2020 | 3 | 84 |
| 2018 | 1 | 482 |
| 2015 | 1 | 242 |
| 2013 | 2 | 114 |
| 2012 | 3 | 117 |
| 2011 | 2 | 126 |
Who submits
12 applicants cleared a MRN device since 2011. 100% of the clearances went to applicants in United States. By type: Special 57% and Traditional 43%.
| Applicant | Clearances since 2011 |
|---|---|
| Mallinckrodt Manufacturing, LLC | 4 |
| Ino Therapeutics | 3 |
| Linde Gas & Equipment, Inc. | 3 |
| Ino Therapeutics, LLC/Dba Ikaria | 2 |
| Ino Therapeutics/Ikaria | 2 |
| Airgas Therapeutics | 1 |
| Airgas Therapeutics, LLC | 1 |
| Geno, LLC | 1 |
How FDA classifies it
Class II. The special control for this device is FDA's “Guidance Document for Premarket Notification Submissions for Nitric Oxide Administration Apparatus, Nitric Oxide Analyzer, and Nitrogen Dioxide Analyzer.”
From 21 CFR 868.5165.
Standards
21 CFR 868.5165 names no consensus standards. Check FDA’s recognized standards database, or ask which standards recent MRN clearances declared.
Ask about MRN
Questions about MRN
What is FDA product code MRN?
Product code MRN, “Apparatus, Nitric Oxide Delivery” in FDA's classification database, is a Class II device type under 21 CFR 868.5165 (nitric oxide administration apparatus), reviewed by FDA's Anesthesiology panel. FDA's 510(k) database lists 33 clearances under MRN, 21 of them since 2011.
How many 510(k) clearances are there under MRN?
FDA’s 510(k) database listed 33 clearances under MRN as of Oct 29, 2026, 21 of them decided since 2011; the most recent decision was Jan 17, 2025. The Predicate Finder searches the live database.
How long does FDA take to clear a MRN 510(k)?
For the 2 MRN clearances decided in the two years before Oct 29, 2026, the median time from FDA receiving the 510(k) to its decision was 144 days. That counts calendar days, including time the submission was on hold waiting for answers from the submitter.
Which companies have the most MRN clearances?
Since 2011: Mallinckrodt Manufacturing, LLC (4), Ino Therapeutics (3), Linde Gas & Equipment, Inc. (3), Ino Therapeutics, LLC/Dba Ikaria (2) and Ino Therapeutics/Ikaria (2). 12 applicants have cleared a MRN device in that time.