MCW: Catheter, Peripheral, Atherectomy

Product code MCW, “Catheter, Peripheral, Atherectomy” in FDA's classification database, is a Class II device type under 21 CFR 870.4875 (intraluminal artery stripper), reviewed by FDA's Cardiovascular panel. FDA's 510(k) database lists 146 clearances under MCW, 77 of them since 2011.
Updated Oct 29, 2026 · Clearances from FDA’s 510(k) database, as of Oct 29, 2026
Product code
MCW
Regulation
21 CFR 870.4875
Class
II
Panel
Cardiovascular
Clearances
146
Most recent
Apr 10, 2026
Median review, last 2 years
46 days
Third-party review
Eligible
Implant
No

What it covers

An intraluminal artery stripper is a device used to perform an endarterectomy (removal of plaque deposits from arterisclerotic arteries.)

The identification in 21 CFR 870.4875, intraluminal artery stripper. FDA gives MCW no definition of its own, so the regulation’s describes it.

Recent clearances

510(k)DeviceApplicantDecisionType
K260244Auryon Atherectomy SystemEximo MedicalApr 10, 2026Traditional
K250723FreedomFlow™ Orbital Circumferential Atherectomy System (H6005/ 4Fr 3-Sphere Configuration)Cardio Flow Inc.,Apr 25, 2025Special
K250385Turbo-Elite Laser Atherectomy CatheterSpectraneticsMar 13, 2025Special
K242757Rotarex Atherectomy SystemBard Peripheral Vascular, Inc.Jan 30, 2025Special
K242947FreedomFlow™ Orbital Circumferential Atherectomy SystemCardio Flow Inc.,Nov 5, 2024Special
K241553Auryon Atherectomy Catheter 1.7mm; Auryon Atherectomy Catheter 1.7mm, Hydrophilic CoatingEximo Medical, Ltd.Jun 27, 2024Special
K233483FreedomFlow Orbital Circumferential Atherectomy System (H6004/5Fr 3-Sphere Configuration)Cardio Flow Inc.,Feb 15, 2024Special
K233668Auryon Atherectomy Catheter 1.5 mm XL, Hydrophilic Coating (EXM-4010-H000), Auryon Atherectomy Catheter 0.9 mm XL, Hydrophilic Coating (EXM-4011-H000), Auryon Atherectomy Catheter 1.5 mm XL (EXM -4010-0000), Auryon Atherectomy Catheter 0.9 mm XL (EXM-4011-0000)Eximo Medical, Ltd.Dec 15, 2023Special
K231538FreedomFlow Orbital Circumferential Atherectomy SystemCardio Flow Inc.,Sep 27, 2023Traditional
K230709Auryon Atherectomy SystemEximo Medical, Ltd.Jun 9, 2023Special
From FDA’s 510(k) database, as of Oct 29, 2026Export CSV (100 rows free · all 146 with a free account)

Clearances by year

77 MCW 510(k)s were cleared from 2011 to Oct 29, 2026. Days to decision run from the day FDA received the 510(k) to its decision, including time on hold.

YearClearancesMedian days to decision
2026 (so far)173
2025346
2024341
20234104
2022669
20216119
2020259
20193112
20188103
2017791
2016560
2015630
20147117
2013530
2012529
2011639

Who submits

28 applicants cleared a MCW device since 2011. 88% of the clearances went to applicants in United States, then Israel (10%) and Switzerland (1%). By type: Traditional 51% and Special 49%. 1 went through a third-party review organization.

ApplicantClearances since 2011
Cardiovascular Systems, Inc.13
Avinger, Inc.10
Eximo Medical, Ltd.7
Spectranetics, Inc.6
Volcano Atheromed, Inc.6
Cardio Flow Inc.,4
Medrad, Inc.3
Pathway Medical Technologies, Inc.3

How FDA classifies it

Class II (performance standards).

From 21 CFR 870.4875.

Standards

21 CFR 870.4875 names no consensus standards. Check FDA’s recognized standards database, or ask which standards recent MCW clearances declared.

Ask about MCW

US FDA devices: 510(k), De Novo, guidance, 21 CFR

Questions about MCW

What is FDA product code MCW?

Product code MCW, “Catheter, Peripheral, Atherectomy” in FDA's classification database, is a Class II device type under 21 CFR 870.4875 (intraluminal artery stripper), reviewed by FDA's Cardiovascular panel. FDA's 510(k) database lists 146 clearances under MCW, 77 of them since 2011.

How many 510(k) clearances are there under MCW?

FDA’s 510(k) database listed 146 clearances under MCW as of Oct 29, 2026, 77 of them decided since 2011; the most recent decision was Apr 10, 2026. The Predicate Finder searches the live database.

How long does FDA take to clear a MCW 510(k)?

For the 5 MCW clearances decided in the two years before Oct 29, 2026, the median time from FDA receiving the 510(k) to its decision was 46 days. That counts calendar days, including time the submission was on hold waiting for answers from the submitter.

Which companies have the most MCW clearances?

Since 2011: Cardiovascular Systems, Inc. (13), Avinger, Inc. (10), Eximo Medical, Ltd. (7), Spectranetics, Inc. (6) and Volcano Atheromed, Inc. (6). 28 applicants have cleared a MCW device in that time.

Sources

  1. FDA product classification: MCW · Product Classification database
  2. 21 CFR 870.4875: Intraluminal artery stripper · eCFR, as of Oct 27, 2026
  3. openFDA 510(k) query for MCW · run Oct 29, 2026
  4. 510(k) Premarket Notification database · FDA, accessdata.fda.gov
Follow MCWGet an email when FDA clears, recalls or publishes guidance for MCW devices.

Know what FDA already cleared.